Replacing a gas water heater takes seven stages: shut off gas and water, drain the tank, disconnect the old unit, set the new tank on a pan, connect water, gas and the flue, fill and purge, then light and test. Most of it is plumbing work a careful person can follow. The gas connection and the flue are the two parts where a mistake can hurt someone.
This guide walks through each stage so you know what a good job looks like, even if a licensed plumber does the work. If you want it done today, our water heater replacement service is available around the clock.
First Things FirstSafety Comes Before Any Wrench
Stop and call a pro if any of these are true
- You smell gas or hear a hiss near the heater
- The flue pipe is rusted, loose or disconnected
- You are not sure the gas shutoff closes fully
- The tank is in a closet with no clear vent path
- You have no experience with gas fittings
If you smell gas, leave the building first. Then call 911 and the gas utility. Enbridge Gas lists 1-800-767-1689 for gas emergencies in Utah. Do not flip switches or use a phone inside until the building is cleared.
Step By StepThe Seven Stages Of A Swap
Shut off
Close the gas valve on the supply line and the cold water inlet. Switch the control to off.
Drain
Attach a hose to the drain valve, open a hot tap upstairs and let the tank empty outdoors or into a floor drain.
Disconnect
Unscrew the gas flex line, disconnect the water lines and lift the flue pipe from the draft hood.
Set the new tank
Place the tank on a drain pan and level it. Strap it in the upper and lower thirds.
Connect water
Use new flex connectors or copper with dielectric fittings where dissimilar metals meet.
Connect gas and flue
Use a new gas connector, apply approved thread sealant and check every joint for leaks.
Fill and purge
Open the cold inlet and a hot tap and let the tank fill before turning the gas on.
Light and test
Follow the label to light the unit, check the flame and make sure the flue draws.
Never fire a gas heater with an empty tank. The burner can damage the tank in minutes and the repair is not covered by most warranties.
Where Mistakes HappenGas Joints And The Flue Are The Hard Part
Gas joints must be sealed with sealant rated for gas, not tape made for water lines. After tightening, brush soapy water over each joint. Bubbles mean a leak and the joint needs to be redone before the unit is lit.
The flue carries exhaust out of the house. It needs a continuous upward slope, tight joints and a clear termination. A flue that backdrafts can put carbon monoxide into the living space, so a working CO alarm near the heater is not optional.
Utah DetailsStrapping, Pans And Relief Valves
Utah statewide amendments to the plumbing code call for strapping in the upper and lower thirds of the tank. The same amendments set rules for drain pans and the pan drain line where a leak could damage finished space. The relief valve discharge pipe should end where hot water cannot hurt anyone.
| Task | Reasonable for a handy owner | Better for a licensed plumber |
|---|---|---|
| Draining and removing the old tank | Yes, with help | Optional |
| Setting the new tank and strapping | Yes, with help | Optional |
| Water connections | Yes, if comfortable with plumbing | Recommended |
| Gas connection and leak check | Not recommended | Yes |
| Flue and draft check | Not recommended | Yes |
| Permit and inspection | Owner may pull a permit where allowed | We confirm what applies |
When A Replacement Is Smarter Than A Repair
If the tank leaks from its body, replacement is the only fix. If it is only a thermostat, valve or pilot, a repair may be enough. Our water heater repair page has a table of symptoms and likely fixes.
If you are planning a swap in advance, ask whether the same location still makes sense. Moving the unit changes gas piping and venting, and the plan is easier to price when everyone knows the scope. We also install in nearby towns, including American Fork, and the service areas page lists the rest.
Questions about your own house? Call (385) 488-1892 and a person will answer.
Utah applies the International Plumbing Code (IPC) with state amendments to water heater work. The amendments call for strapping in the upper and lower thirds of the tank and for a pan drain where the heater could leak onto a finished floor.
FAQsGas Water Heater Replacement Questions
Most swaps take a few hours for a plumber and longer for a first timer. Add time for draining, which can take more than half an hour.
No. Use a new connector rated for gas, and leak test every joint after tightening.
The city page we reviewed does not say. Call Lehi Building and Inspections at (385) 201-1035 and ask before you start.
Utah amendments call for straps in the upper and lower thirds of the tank so it stays upright if the ground moves.
Leave the house, then call 911 and the gas utility. Do not relight the unit until a licensed plumber has checked it.